Lamp (bulb) replacement
Replacement lamp details can be found on the label around the
cap. Handle lamps around the rim taking care not to touch the centre.
It is important that, to maintain the fire safety and sound insulation
properties of your Snaplite downlighter that the correct replacement
lamps are fitted. |
 |
|
 |
|
 |
| |
|
|
|
|
| Press one side of the lamp assembly against the spring retainer
and the lamp assembly detaches itself from the bezel |
|
Push the red cap forward and pull used lamp from the assembly |
|
Holding the rim of the replacement lamp, align pins
and push firmly home. Holding the wires gently, push the red cap
until its skirt sits cleanly on the rear of the assembly. Snap the
assembly back into the bezel. |
Please read before installation
All downlighters must be installed by a competent person registered
to an approved Buiding Regulations Part P scheme or this new electrical
work must be notified to your local Building Control Department before
installation commences.
Lathe and Plaster Ceilings (see additional installation instructions)
We recommend that our outer shield (FS-OS)is fitted to take up any irregularities
around the cut out.Please contact 0870 443 7735 to purchase additional
shields when not supplied as standard.
Operating under insulation
The ideal location is a well ventilated one.
However, with modern building requirements this is not always possible.
Snaplite and its transformer have been designed and tested such that
they will operate together perfectly when covered by insulation. However,
do not fit in shallow voids where the downlighter and transformer are
compressed by the insulation. The transformer is supplied pre-cabled
to a length of 0.5M and it is good practice to place the transformer
at the maximum distance possible from the downlighter. (both items are
sources of heat and placing them far apart minimises their effect on
the void ambient temperature)
Installation instructions 30 minute versions (plasterboard ceilings)
 |
|
 |
|
 |
| |
|
|
|
|
| Drill a 68mm hole |
|
Connect transformer to 240vac and place in roof space leaving push-on
connector assessable |
|
Snap in bezel |
| |
|
|
|
|
 |
|
 |
|
|
| |
|
|
|
|
| Connect the lamp assembly to the push-on transformer connection |
|
Snap in the light assembly |
|
|
Additional Installation Instructions 60 minute versions (30 minute lathe
and plaster ceilings)
 |
|
 |
|
 |
| |
|
|
|
|
| Drill a 68mm hole |
|
Insert shield through the hole |
|
Bend fingers over Continue steps 2-5 above |
Please note that the latest production versions of the 60 minute fire
rated Snaplite no longer require the use of the supporting stay.
|